Process Capabilities

Equipment Features

Typical Components Processed

Technical Data

Companion Equipment


 |
 |
Technical Data
Model (1) Fluidcarb |
Useful load size W x L x H (CM) |
Connected Load (heating) (2) |
Gross capacity KG@950°C |
Atmosphere consumption M3 / HR |
Quenchant volume (LT) |
| Furnace |
Oil quench tank (KW)3 |
| KW (E) |
KCAL / HR x1000(G) |
Warm |
Hot |
| E-250 |
50/75/45 |
45 |
100 |
9 |
24 |
250 |
7 |
2800 |
| E/G-350 |
60/90/45 |
54 |
114 |
15 |
36 |
350 |
8 |
3000 |
| E/G-500 |
60/90/60 |
60 |
125 |
15 |
36 |
500 |
12 |
3300 |
| E/G-650 |
75/100/60 |
100 |
196 |
21 |
54 |
650 |
15 |
7250 |
| E/G-1000 |
75/120/75 |
145 |
250 |
30 |
66 |
1000 |
18 |
10000 |
| E/G-1300 |
90/120/75 |
160 |
350 |
37 |
72 |
1300 |
22 |
12000 |
| E/G-2700 |
90/180/90 |
210 |
500 |
54 |
118 |
2700 |
30 |
18000 |
|
- All models available in two types; in-out (single side entry/exit) or straightthrough (entry one side & exit on the other). E = Electrically heated G = Gas fired.
- Motor power rating extra and will depend on configuration & options.
Custom sizes & configutations available on request All figures are approx. and subject to change due to constant innovation.
- No heating in polymer quench furnaces.

|